PRODUCT Overview

The following are guidelines to generally help in the selection of our product systems. Local codes, seismic zones and calculated floor loads may require a selection not specifically shown in these charts. Camino offers a variety of pedestal base styles for different lateral load requirements. Please contact your Camino Sales Team to verify your specific requirements before specifying any modular floor system.

Building Application Duty/Performance Floor System/Understructure Air Distrib. Min. Finished Floor Height Modular Power Min. Finished Floor Height Available Factory Finishes Field Finishes
Office: Low-rise Light Duty/Class B Fire WC Series 1000 / Corner Bolt 12" to 18" 2.5" to 6" Bare (WC) Carpet Tile
Office - Mid Rise Standard Duty/Class A Fire SC Series 1250 / Corner Bolt 12" to 18" 2.5" to 6" Bare (WC) Carpet Tile
Office - Tower Standatd Duty/Class Non-Combustible TecCrete 1250 Series and FS 1250 Series / Corner Bolt 12" to 18" 3" to 6" Bare (TecCrete) Carpet Tile, Field Sealed Exposed Concrete ( TecCrete Only)
Office: Low-rise Heavy Duty/Class B Fire WC Series 1500 / Stringered 12" to 18" 2.5" to 6" Rubber, Vinyl, VCT Carpet Tile
Office - Mid Rise Heavy Duty/Class A Fire SC Series 1500 / Stringered 12" to 18" 2.5" to 6" Rubber, Vinyl, VCT Carpet Tile
Office - Tower Heavy Duty/Class A Non-Combustible TecCrete 1500 Series and FS 1500 Series / Stringered 12" to 18" 2.5" to 6" Bare (TecCrete) Rubber,
Vinyl, VCT (FS)
Bare (TecCrete)
Office / Lobby - Specialty Finish Standard Duty/Class A Fire SC Series Stringered 12" to 18" 2.5" to 6" Camino Composite Stone n/a
Office / Lobby - Specialty Finish Standard Duty/Class A Non-Combustible Tecnika / Stringered 12" to 18" 3" to 6" Tecnika Composite Stone n/a
Building Application Duty/Performance Floor System/Understructure Air Distrib. Min. Finished Floor Height Modular Power Min. Finished Floor Height Available Factory Finishes Field Finishes
Classroom / Lecture Hall Standard Duty / Class A Fire SC Series 1250 / Corner Bolt 12" to 18" 2.5" to 6" Bare (SC) Carpet Tile
Classroom / Lecture Hall Standard Duty / Class A Non-Combustible TecCrete 1250 Series / Corner Bolt 12" to 18" 3" to 6" Bare (TecCrete) Carpet Tile, Field Sealed-Exposed Concrete
Classroom / Lecture Hall Heavy Duty / CLass A Fire SC Series 1500 / Stringered 12" to 18" 2.5" to 6" Rubber, Vinyl, VCT Carpet Tile
Classroom / Lecture Hall Heavy Duty / Class A Non-Combustible TecCrete 1500 series / Stringered 12" to 18" 2.5" to 6" Bare (TecCrete) Carpet Tile, Field Sealed-Exposed Concrete
Building Application Duty/Performance Floor System/Understructure Air Distrib. Min. Finished Floor Height Modular Power Min. Finished Floor Height Available Factory Finishes Field Finishes
Casino / Exhibition / Museum Heavy Duty / Class A Non-Combustible FS Series 2000 / Stringered 12" to 18" 2.5" to 6" Rubber, Vinyl, VCT Carpet Tile
Casino / Exhibition / Museum Extra heavy-Duty / Class A Non-Combustible FS Series 2500 / Stringered 12" to 18" 2.5" to 6" Rubber, Vinyl, VCT Carpet Tile / Broodloom
Casino / Exhibition / Museum Standard Duty / Class A Fire SC Series Stringered 12" to 18" 2.5" to 6" Camino Composite Stone n/a
Casino / Exhibition / Museum Standard Duty / Class A Non-Combustible Tecnika Stringered 12" to 18" 3" to 6" Tecnika Composite Stone n/a
Building Application Duty/Performance Floor System/Understructure Air Distrib. Min. Finished Floor Height Modular Power Min. Finished Floor Height Available Factory Finishes Field Finishes
Electrical Closet / Computer Room Light Duty / Class B Fire WC Series 1000 or 1500 / Stringered 12" to 18" 6" Static Dissipative or Conductive HPL, Rubber, Vinyl Floor system grounding protection recommended
Electrical Closet / Computer Room Standard Duty / Class A Fire SC Series 1250 and 1500 / Stringered 12" to 18" 6" Static Dissipative or Conductive HPL, Rubber, Vinyl Floor system grounding protection recommended
Electrical Closet / Computer Room Standard Duty / Class A Non-Combustible TC Series 1250 and 1500 / Stringered 12" to 18" 6" Bare Concrete (sealed in field by others) Floor system grounding protection recommended
Data Center / Mission Critical Facility Class A Non-Combustible FS Series 1500 / Stringered 12" to 18" 6" Static Dissipative or Conductive HPL, Rubber, Vinyl Carpet Tile, Field Sealed-Exposed Concrete
Data Center / Mission Critical Facility Class A Non-Combustible FS Series 2000 Stringered 12" to 18" 6" Static Dissipative or Conductive HPL, Rubber, Vinyl Floor system grounding protection recommended
Data Center / Mission Critical Facility Extra Heavy / Class A Non-Combustible FS Series 2500 / Stringered 12" to 18" 6" Static Dissipative or Conductive HPL, Rubber, Vinyl Floor system grounding protection recommended
Building Application Duty/Performance Floor System/Understructure Air Distrib. Min. Finished Floor Height Modular Power Min. Finished Floor Height Available Factory Finishes Field Finishes
Library / Gallery Standard Duty / Class A Fire SC Series 1250 / Corner Bolt 12" to 18" 2.5" to 6" Bare (SC) Carpet Tile
Library / Gallery Standard Duty/Class A Non-Combustible TC Series 1250 / Corner Bolt 12" to 18" 2.5" to 6" Bare (TecCrete) Carpet Tile
Library / Gallery Heavy Duty / Class A Fire SC Series 1500 / Stringered 12" to 18" 3" to 6" Rubber, Vinyl, VCT Carpet Tile, Field Sealed-Exposed Concrete
Library / Gallery Heavy Duty/Class A Non Combustible TC Series 1500 / Stringered 12" to 18" 2.5" to 6" Bare (TecCrete) Carpet Tile, Field Sealed-Exposed Concrete
Library / Gallery Standard Duty / Class A Fire SC Series 1500 Stringered 12" to 18" 2.5" to 6" Camino Composite Stone n/a
Library / Gallery Standard Duty / Class A Non-Combustible Tecnika Stringered 12" to 18" 3" to 6" Tecnika Composite Stone n/a